A 1930s semi: opening up the back.
Illustrative diagram
The house
A 1930s semi, three small rooms across the back. The wall between kitchen and dining is in the way.
The ask
One kitchen-diner, no post in the middle. The dashed outline is the wall that goes.
The constraint
The joists run the same way as the wall, so they pass it rather than land on it. It carries the wall above, and braces the house sideways.
What we would do
A beam along the old wall line, flush in the floor so the ceiling runs through. A padstone at each end, down to a foundation, then a check the house is still braced.
Key to the drawings
- Existing masonry A flat tone: everything already there, cut or seen.
- Brickwork, new Single diagonal hatch. The outer leaf, and new brickwork in elevation.
- Blockwork, new Cross-hatch, so it can never be read as brick beside it.
- Concrete Aggregate triangles and fine dots, scattered at random: foundations, slabs, padstones, lean-mix cavity fill, encasement.
- Undisturbed ground Basket weave, as a band that follows the ground line and fades out.
- Hardcore Large open zigzag, the depth of its own layer.
- Insulation board The looped line, touching both faces, inside the board outline.
- Compressible heave board A close zigzag in a thin outlined strip. It squashes as the clay swells, so the clay pushes the foundation far less.
- Void former A row of open cells in an outlined band, under a suspended slab. It collapses to leave a gap the clay can rise into.
- Timber, cut A box with a cross. Seen along its length, an outline only.
- Steel, cut Solid, at the section's true proportion.
- Reinforcement A line along the bar, a dot where a bar is cut.
- DPC Heavy dashed line, as Approved Document C draws it.
- Membrane, tray Heavy solid line: DPM, cavity tray, roof membrane.
- Load path Where the load goes, from the roof to the ground; dashed where it runs beyond the cut.
- Load marks Arrows at the symbol weight: loads down onto a member, bearing up under a foundation.
- Hidden, beyond or removed Out of the cut, beyond it, or taken out.
- By others, beyond Faint: frames, coverings. Not our structure.
- Span Half barbs, the way the joists run. Dashed where existing.
- Inset zone Chain line round what is drawn again, larger, in an inset.
- Cloud Confirm on site. Never a revision mark.
- Break line The drawing stops; the building does not.
Illustrative image